Every standard extinguisher in a UK building has a red body. What tells them apart is a coloured band or panel near the top: none (plain red) for water, cream for foam, black for CO2, blue for dry powder and yellow for wet chemical. Whether you run an office in Spinningfields, a takeaway in Rusholme or a joinery unit in Wigan, that band is the quickest way to grab the right one. The printed label on the body then confirms exactly which fires it is rated for. This is general guidance; the number, type and position of extinguishers on your premises come from your fire risk assessment.

The colour chart

Band Contents Use on Keep it away from
Plain red Water Class A: paper, wood, fabric Electrics, fryers, flammable liquids
Cream Foam Class A and class B liquids Chip pans and fryers
Black CO2 Electrical kit, class B liquids Fryers; weak on paper and wood
Blue Dry powder Classes A, B, C and electrical Fryers; small enclosed rooms
Yellow Wet chemical Class F cooking oil and fat (many also class A) Anything its label does not list

Water conducts electricity and spreads burning fuel, hence the long list of places to avoid. Only some foam units are tested near electrics, so read yours. CO2 leaves no mess, but a paper fire can reignite once the gas clears. Powder covers most classes, yet its cloud makes seeing and breathing hard in a confined room. Water mist ratings vary by maker.

The fire classes in one minute

Start from what is burning and the colours stick:

  • A: solid materials such as cardboard, timber, textiles.
  • B: flammable liquids such as petrol, diesel, paint and solvents. Never water.
  • C: flammable gases such as propane and butane. Shut off the supply if safe.
  • D: burning metals, for example magnesium or aluminium swarf. These need a specialist powder.
  • F: cooking oils and fats. Wet chemical only.

The UK has no class E. Electrical risk is shown by a symbol on the extinguisher label instead.

Why they are not fully coloured any more

Until the late 1990s, UK extinguishers were coloured all over by contents. BS EN 3 moved everything to red with a coloured zone. Still got an all-black or all-cream unit? Ask your service engineer about replacing it.

Typical set-ups by premises

A starting point for your fire risk assessor, not an order list:

  • Offices and shops: water or foam for general combustibles, plus a black-band CO2 near IT and the distribution board.
  • Cafe and restaurant kitchens: a yellow-band unit and a fire blanket close to the fryer, with other cover for the dining area and stores.
  • Garages and fuel stores: foam or powder, CO2 near electrical plant, and possibly a larger wheeled unit.
  • Vans and site plant: a compact powder or foam unit matched to what is carried.

GOV.UK's workplace fire safety guidance sets out who is responsible and the duty to provide suitable equipment.

Signs that lead people to the extinguisher

A band colour only helps once you have found the unit. Fire equipment signs are white on red, and ISO 7010 codes the extinguisher symbol F001. Fix the sign above the extinguisher, clear of heads and shelving, especially where it sits in a cabinet or round a corner.

Manchester Printed fire safety signs include F001 extinguisher signs from A4 (210 × 297 mm) to A1 (594 × 841 mm), plus call point, assembly point and exit signs, in 3 mm Foamex, 3 mm Dibond or self-adhesive vinyl. Production is 4 working days on Standard or 2 on Express. Want a small panel by each unit repeating its band and use? That is a custom job through the quote form. For the legal side, read safety signs and the law.

Service labels for engineers

A competent person should service extinguishers regularly, and most engineers note each visit on a label stuck to the body. Our fire engineer labels come in 76 × 51 mm or 96 × 68 mm, printed with your company details and write-on lines for service date, next due date, engineer and extinguisher type. For damp plant rooms or outdoor units, choose polypropylene; paper or polypropylene labels explains the difference.

What else do people ask?

What colour is a CO2 extinguisher?

A red body with a black band or panel. It suits electrical equipment and flammable liquids, not cooking oil.

Which extinguisher do I need for a deep fat fryer?

The yellow-band wet chemical type, rated for class F. Water, foam, CO2 and standard powder are all unsuitable on burning fat.

Is there a class E fire in the UK?

No. Electrical hazards are shown with a symbol on the extinguisher label rather than a separate class.

How do I teach staff the colours?

Walk new starters past each extinguisher at induction, naming the band and its use. It beats any poster.

Buy with confidence

A real company, a real address and a real person on the phone.

Who we are

FAT PRINT LTD

Registered in England and Wales, company no. 17494787

Unit 3, 116 Bury New Road, Manchester M8 8EB

Refund promise

Change your mind before we print and we refund you in full. Faulty, damaged or wrong items are put right or refunded.

Read the returns and refunds policy

Secure payment

Card payments are handled by Stripe. We never see or store your card number.

VisaMastercardAmerican ExpressApple PayGoogle Pay
WhatsApp